Forms complete film formation on needle surfaces and lubricates needles perfectly
Composed of nonionic/anionic emulsifiers, anti wear and anticorrosion additives
8-13% emulsifier admixed with white oil gives clear transparent knitting oil product
Emulsifier does not deteriorate its colours and forms complete film formation and perfect lubrication on needles
Heat resistant emulsifier package does not interact with knitted fabric surface during heat fixation step and supplies perfect scouring & washing effect.
Frame made of aluminium profile bars connected by "Tox" connections
- All-round EPDM lip seal
- Restraint security
- Hidden latches
- Screwed GKF gypsum plasterboard
Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018EN 1634-1: +A1: 2018
Fire dampers EI 60 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 60.
They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop.
The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.
Simat celebra su 40 aniversario este año 2019. Lo hace manteniendo la ilusión de su fundador, la que le ha traído hasta hoy y también mirando hacia el futuro y adaptando sus productos a las necesidades actuales de consumo. Ofrece para ello productos sin gluten, ninguno lo contiene, con valores equilibrados nutricionalmente, bajos en grasas y sin azúcares añadidos. Así mismo, ofrece formatos nuevos que facilitan su uso adaptándose así al ritmo de vida de nuestros días.
Als Spezialist für eingebettete Systeme verfügen wir über große Erfahrung im Bereich der Firmware-Entwicklung und Firmware-Erstellung für diverse Controller und Prozessoren
Frame made of aluminium profile bars connected by "Tox" connections
- All-round EPDM lip seal
- Restraint security
- Hidden latches
- Screwed GKF gypsum plasterboards
Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018
Fire dampers EI 120 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 120.
They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop.
The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.